實(shi)(shi)驗(yan)(yan)室(shi)供排風系(xi)(xi)(xi)統是整個實(shi)(shi)驗(yan)(yan)室(shi)設計和建設過(guo)程中規模大(da)、影(ying)響(xiang)廣泛(fan)的(de)系(xi)(xi)(xi)統之一。供排風系(xi)(xi)(xi)統完善(shan)與否,直接對實(shi)(shi)驗(yan)(yan)室(shi)環境(jing)、實(shi)(shi)驗(yan)(yan)人員的(de)身體(ti)健康、實(shi)(shi)驗(yan)(yan)設備的(de)運行維護(hu)等方面產生重要(yao)影(ying)響(xiang)。
實驗室內往(wang)往(wang)存在許多不利(li)于人體健(jian)康(kang)的(de)(de)化學(xue)物質污(wu)染源,特別是(shi)有害(hai)氣體,將其排(pai)除非常重要(yao)(yao)。但(dan)與此同時,能(neng)(neng)源往(wang)往(wang)會被大(da)量(liang)的(de)(de)消耗,因而實驗室的(de)(de)通(tong)風(feng)控制系(xi)統(tong)(tong)的(de)(de)要(yao)(yao)求漸(jian)高,從早期CV(定風(feng)量(liang)),2-State(雙穩(wen)態式),VAV(變風(feng)量(liang))系(xi)統(tong)(tong),到(dao)適應性控制系(xi)統(tong)(tong)——既安全,又(you)要(yao)(yao)符合節約能(neng)(neng)源的(de)(de)需(xu)要(yao)(yao)。總之,實驗室通(tong)風(feng),就(jiu)是(shi)把室內的(de)(de)污(wu)濁空(kong)氣直接或(huo)經凈化后排(pai)至室外把新(xin)鮮空(kong)氣補充進來,從而保持室內的(de)(de)空(kong)氣條件,以保持衛生標準(zhun)和滿足(zu)生產工藝的(de)(de)要(yao)(yao)求,我們(men)把前者(zhe)稱為(wei)(wei)排(pai)風(feng),后者(zhe)稱為(wei)(wei)送風(feng)。
實驗室通風系統
二、實驗室(shi)通風要求(qiu):
保持(chi)實驗(yan)室適當的通風
有(you)人模式:?每小時(shi)換(huan)氣次數不(bu)少于10次
無(wu)人模式:?每小時換氣次(ci)(ci)數4次(ci)(ci)
保持實(shi)驗室(shi)的壓差(cha)(正壓或負壓)
保持(chi)適當的實驗室的環境條件
溫度?濕(shi)度?穩定(ding)性?
三、實驗室通風空(kong)調系統的設計要考慮以下幾個主要因素:
(1)保證(zheng)實驗室的安全性,保證(zheng)一定數(shu)量的換氣次數(shu)。?
(2)解決實(shi)驗室(shi)通風系(xi)(xi)統負壓的設計和系(xi)(xi)統控制(zhi)。
(3)在滿足換氣次數和全(quan)新風條件下,控制能耗。
(4)系(xi)統穩定可(ke)靠。?
實(shi)(shi)驗(yan)室(shi)通(tong)風要求新(xin)風全(quan)部(bu)來自室(shi)外(wai)(wai),然后(hou)100%排出室(shi)外(wai)(wai),通(tong)風柜(ju)的(de)排氣(qi)(qi)不在(zai)室(shi)內(nei)循環。化學(xue)實(shi)(shi)驗(yan)室(shi)換氣(qi)(qi)要求每小時(shi)大(da)于10次(ci),物理實(shi)(shi)驗(yan)室(shi)每小時(shi)大(da)于10次(ci),實(shi)(shi)驗(yan)室(shi)無(wu)人時(shi)換氣(qi)(qi)可減少為6次(ci)。
實(shi)(shi)驗(yan)室(shi)通(tong)風(feng)(feng)(feng)(feng)柜(ju)(ju)設計數(shu)量要(yao)足夠,并且(qie)不作為室(shi)內(nei)排風(feng)(feng)(feng)(feng)裝置(zhi)(zhi),儀器室(shi)或產生(sheng)危險物(wu)質(zhi)(zhi)的(de)(de)儀器上(shang)方(fang)(fang)(fang)設局部(bu)排風(feng)(feng)(feng)(feng)系(xi)統(tong)。實(shi)(shi)驗(yan)室(shi)的(de)(de)補(bu)風(feng)(feng)(feng)(feng)一部(bu)分(fen)來自空調系(xi)統(tong)直接送入實(shi)(shi)驗(yan)室(shi)的(de)(de)新(xin)風(feng)(feng)(feng)(feng),這(zhe)部(bu)分(fen)新(xin)風(feng)(feng)(feng)(feng)根據實(shi)(shi)驗(yan)室(shi)排風(feng)(feng)(feng)(feng)量的(de)(de)變化而變化;另一部(bu)分(fen)通(tong)過(guo)空調系(xi)統(tong)送入非實(shi)(shi)驗(yan)室(shi)區(qu)域的(de)(de)走(zou)道、房(fang)間再通(tong)過(guo)實(shi)(shi)驗(yan)室(shi)的(de)(de)門縫補(bu)給。實(shi)(shi)驗(yan)室(shi)的(de)(de)負壓通(tong)過(guo)送、排風(feng)(feng)(feng)(feng)風(feng)(feng)(feng)(feng)量和送排風(feng)(feng)(feng)(feng)口的(de)(de)布(bu)置(zhi)(zhi)來實(shi)(shi)現,氣(qi)流組織從辦(ban)公、管(guan)理用房(fang)、內(nei)走(zou)道、到產生(sheng)危險物(wu)質(zhi)(zhi)的(de)(de)實(shi)(shi)驗(yan)房(fang)間。通(tong)風(feng)(feng)(feng)(feng)柜(ju)(ju)的(de)(de)位置(zhi)(zhi)布(bu)置(zhi)(zhi)在遠(yuan)離(li)空氣(qi)流動、紊(wen)流大的(de)(de)地(di)方(fang)(fang)(fang),遠(yuan)離(li)行走(zou)區(qu)域和空氣(qi)新(xin)風(feng)(feng)(feng)(feng)區(qu)。新(xin)風(feng)(feng)(feng)(feng)從遠(yuan)離(li)通(tong)風(feng)(feng)(feng)(feng)柜(ju)(ju)的(de)(de)地(di)方(fang)(fang)(fang)引(yin)入,空氣(qi)流動路徑遠(yuan)離(li)通(tong)風(feng)(feng)(feng)(feng)柜(ju)(ju)。?
此次工程地點:西安
項目內(nei)容:實驗室通風建設(she)工程(排風、送風、電路(lu)、廢氣(qi)處理(li)系統(tong)等(deng))